Solucionando problemas comuns de forno com um especialista em HVAC

Solucionando problemas comuns de forno com um especialista em HVAC



We are searching data for your request:

Forums and discussions:
Manuals and reference books:
Data from registers:
Wait the end of the search in all databases.
Upon completion, a link will appear to access the found materials.

Descobrindo os problemas do forno

Antes de chamar os profissionais, por que não tentar consertar o forno sozinho?

Trabalho na indústria de HVAC há mais de 23 anos. Há muitas coisas que podem dar errado com uma fornalha, mas muitos problemas são fáceis para qualquer pessoa descobrir e consertar. Mesmo se você precisar de uma peça, não desanime - muitas das peças mais comumente substituídas são fáceis de instalar e geralmente podem ser compradas de um fornecedor local. Suas chances de recuperar o calor mais cedo ou mais tarde não são tão ruins. Abaixo, você encontrará:

  • Uma lista de verificação de solução de problemas do forno.
  • Dicas para reparos comuns em fornos.
  • Um guia de vídeo para ajudá-lo a consertá-lo sozinho.

Lista de verificação de solução de problemas do forno

Abaixo, eu explico cada um desses processos com mais detalhes. Começamos com os problemas mais simples e, em seguida, testamos os problemas mais difíceis. É importante ser metódico e sistemático em seu diagnóstico.

  1. Verifique as configurações do termostato.
  2. Verifique se há energia através do disjuntor, interruptor, luz indicadora e fusível.
  3. Verifique se a válvula de gás em linha está aberta.
  4. Verifique o filtro.
  5. Verifique o ignitor quanto à ignição.
  6. Verifique o sensor de chama para confirmação de ignição.
  7. Verifique se há obstrução da chaminé / chaminé: interruptor de pressão.
  8. Saiba quando chamar um técnico de serviço.

1. Verifique o termostato

Sei que pode parecer bobo, mas antes de nos deixarmos levar, vamos verificar algumas coisas no termostato. Você pode se surpreender com a quantidade de dinheiro gasta por ano com caras como eu ligando os termostatos das pessoas ou trocando as baterias.

Lista de verificação de problema do termostato

Às vezes, grandes problemas têm soluções fáceis.

Verifica...Pode ser ...

para um display digital confuso

precisa ser substituído (podemos testar isso para ter certeza)

para um indicador de bateria piscando

precisa de novas baterias 'AA'

ajuste de temperatura

não ser aumentado o suficiente

seleção de função

não ser colocado em "calor" (desligue e ligue novamente para ter certeza)

dentro para fios soltos ou em contato

só precisa ser apertado ou arrumado

Como testar um termostato

Testar seu termostato é muito fácil. Tudo o que você precisa é de uma chave de fenda pequena ou média e um pedaço curto (6 ") de fio de bitola 18 (que chamaremos de" fio de jumper "). Se você for a uma loja de ferragens, peça" 18/2. "

Simplesmente vá até a fornalha, remova as portas e siga estas etapas.

  1. Localize a placa de circuito onde os fios do termostato se conectam ao forno.
  2. Desconecte os fios conectados aos terminais "R" e "W". (Os fios devem ser vermelhos e brancos, mas nem sempre.) Empurre-os com segurança para o lado.
  3. Conecte seu fio jumper entre os terminais "R" e "W".
  4. Prenda novamente a porta e veja se o forno funciona.

Funcionou?

NÃO: Então, seu termostato não é o problema.

SIM: Então, é provável que seu termostato esteja ruim e precise ser substituído. Podem ser os fios que conectam o termostato ao forno, mas se eles não estiverem soltos, quebradiços ou quebrados, é improvável.

TAMBÉM: Estas instruções são apenas para testar um circuito normal de 24 V (baixa tensão). Em outras palavras, não use essas instruções se estiver solucionando problemas em um circuito de tensão de linha. (120v ou superior)

Termostatos controlados por mercúrio precisam ir

Se você tiver um termostato antigo que detecta a temperatura com uma lâmpada de mercúrio, substitua-o o mais rápido possível. Não é tão preciso quanto os modelos digitais mais recentes e, como contém mercúrio, não é seguro.

Substituindo seu termostato

Se você decidiu que precisa substituir seu próprio termostato após executar as etapas acima, ou se tem uma versão antiga controlada por mercúrio, você precisará selecionar um termostato para usar.

A maioria dos fabricantes de termostatos respeitáveis ​​fornecerá instruções muito claras com suas unidades sobre como instalá-los, e realmente não é muito difícil para o proprietário fazer por si mesmo se você tomar seu tempo e seguir as instruções fornecidas.

Você pode ficar todo extravagante e comprar um termostato Nest que se conecta com sua Alexa e todos os outros dispositivos modernos de automação residencial. Ou, se você for como eu, deseja apenas algo simples, fácil de instalar e fácil de ler. Eu prefiro algo como este Orbit Clear Comfort Thermostat (abaixo).

2. Verifique se há energia para a fornalha

Se você ouvir o forno tentando acender (acender) ou ouvir o soprador funcionando, mas não estiver recebendo nenhum calor, você pode pular esta etapa, porque você tem energia. Caso contrário, verifique o seguinte:

  • O disjuntor desarmou?
  • A chave de serviço no forno está ligada? (A maioria das unidades tem isso montado no forno ou no teto logo acima.)
  • A pequena luz vermelha na placa de circuito do forno está acesa? (A maioria dos fornos modernos tem uma luz indicadora para dizer que está recebendo energia e, se tiver sorte, diga o que pode estar errado.)

Tem poder?

SIM: Ok, então vamos em frente.

NÃO: Então você pode precisar de um eletricista ou profissional de HVAC. Antes de ligar, porém, vamos verificar o fusível na placa de circuito.

A fornalha fundiu um fusível?

A maioria dos fornos modernos possui fusíveis de 3 A na placa de circuito. No entanto, os fusíveis podem estar localizados em outras partes das placas, no caso de alguns fornos. Ele se parece com o fusível de tamanho padrão que você encontra em seu carro e deve ser fácil de encontrar.

Se você tiver uma luz indicadora e ela não estiver acesa ou piscando, esse pode ser o seu problema e é fácil de determinar e corrigir.

Simplesmente retire o fusível da placa e veja se o link interno está queimado e / ou quebrado. Nesse caso, você deve conseguir comprar um na loja local de ferragens ou automotiva. Se você ainda não fez isso, é uma boa ideia manter fusíveis extras disponíveis, pois esse problema é muito comum. Normalmente não é necessário, mas se você puder, obtenha alguns fusíveis de ação rápida de 3 amp. Esses fusíveis da marca Bussmann são perfeitos para fornos.

NÃO tente substituir o fusível por um de outra classificação de amp.

3. Verifique se o gás está ligado

Parece muito simples, mas certamente vale a pena conferir. Já recebi ligações em que crianças brincando ao redor da fornalha giraram botões e interruptores, custando muito aos pais (e cerca de US $ 150).

Você verificou o filtro? (Eu tive que perguntar.)

4. Verifique a luz vermelha piscando

Se houver uma pequena luz indicadora na placa de circuito do forno (geralmente visível através de uma janela minúscula na porta do forno) e ela estiver piscando, ele está tentando ajudar.

Essa luz pisca em uma espécie de código Morse, um número que corresponde a um gráfico localizado em algum lugar da fornalha. Geralmente é nas portas que você remove pela frente. Por exemplo, um "ponto ... ponto ... pausa ... ponto ... ponto ... pausa" seria o número 2, que o gráfico pode dizer que indica algo como "falha de ignição" ou "interruptor de pressão aberto . "

Compreendendo o luz vermelha piscando em sua fornalha irá ajudá-lo a navegar pelos seguintes possíveis problemas que têm uma solução possivelmente simples.

5. Verifique se há bloqueios

Problemas de interruptor de pressão do forno

Às vezes, a pequena luz vermelha indica um interruptor de pressão aberto, o que muitas vezes significa um bloqueio de tubulação / chaminé. Também é possível que o pressostato esteja ruim, mas antes de decidirmos, vamos ver se a chaminé está entupida. Aves e outros pequenos animais fixam residência em gripes quando está muito frio. Verifique isso (e / ou glacê) realizando o seguinte:

  • Remova o cano da chaminé do topo da fornalha para ver se há algo lá. Se você tiver um forno de alta eficiência, isso pode ser difícil, mas os animais são menos prováveis ​​para você. Além disso, verifique do lado de fora para certificar-se de que as extremidades dos tubos estão limpas e não congeladas.
  • Certifique-se de que o pequeno ventilador conectado à chaminé (o ventilador indutor) está funcionando. Caso contrário, você provavelmente precisará de um técnico de serviço.

NÃO Suba no telhado para verificar a chaminé, a menos que esteja totalmente confiante e confortável em fazê-lo. Não vale a pena arriscar já que normalmente o problema não está aí. Ocasionalmente, os pássaros constroem um ninho na chaminé, mas se você não teve problemas até agora neste inverno, provavelmente não é o seu problema. Isso é algo que se torna aparente no início da estação de aquecimento.

6. Verifique a ignição do forno

Isso é facil:

  • Observe e ouça sua fornalha enquanto ela começa a girar. Pouco antes de ouvir o clique da válvula de gás abrindo, você deve ver o ignitor de superfície quente começar a brilhar ou ouvir o clique, clique, clique do seu ignitor. (Você pode até ver essa faísca.) Se você não ver ou ouvir essas coisas, a fornalha interromperá o ciclo.
  • Se o seu ignitor não estiver funcionando, a válvula de gás não ficará aberta até que você substitua o ignitor, porque o sensor de chama está dizendo à válvula que o gás não está sendo aceso.

NOTA: A parte de ignição pode ser complicada porque pode ser o interruptor de pressão que não o deixa acender, então você pode ter que executar algumas verificações nesse interruptor para ter certeza de qual está causando o problema.

  • Se o dispositivo de ignição brilhar ou faiscar, certifique-se de que o gás esteja ligado. Já recebi ligações em que crianças brincando ao redor da fornalha giraram botões e interruptores, custando a seus pais a pena e cerca de US $ 150, portanto, certifique-se de que o gás também esteja ligado.
  • Se o ignitor está funcionando, mas a válvula de gás não abriu, estou inclinado a pedir que você chame um técnico de aquecimento e resfriamento para trabalhar com uma válvula de gás. Este não é um reparo simples e pode causar problemas perigosos se não for feito corretamente.
  • Se você tiver uma luz piloto, verifique se a chama está acesa. Se não, provavelmente este é o seu problema. Tente reacendê-lo. Para um guia fácil sobre isso (com fotos), consulte meu artigo sobre como acender um velho piloto de aquecedor de água. Se não acender, provavelmente você precisa de um novo termopar. São baratos e podem ser comprados na maioria das lojas de ferragens. Apenas certifique-se de medir quanto tempo você precisa antes de ir.

Uma chama da fornalha que continua se apagando

Se sua fornalha acende os queimadores e desliga apenas alguns segundos depois, é quase certo que isso seja uma falha do sensor de chama. Este é um dos problemas mais comuns enfrentados pelos proprietários de casas.

Limpeza e / ou substituição de um sensor de chama é um dos reparos de aquecimento e ar condicionado mais comuns e simples que se pode fazer. Sem dúvida, você deve experimentar por conta própria antes de chamar um técnico de HVAC.

7. Saiba quando ligar para um profissional de HVAC

Além dos itens que discutimos, há muitas outras coisas que podem estar erradas com sua fornalha. Eu identifiquei as soluções simples acima e, se você ainda não diagnosticou o problema, mexer mais no assunto pode agravar o problema e as despesas. Embora você possa não querer, você deve considerar chamar um técnico HVAC profissional.

Por favor, entenda que sempre que você trabalha com uma fornalha, há uma certa quantidade de perigo que requer sua atenção e cuidado. Nunca trabalhe em uma fornalha se não tiver certeza de onde está se metendo e se tomou todas as precauções de segurança possíveis com gás, eletricidade e bordas afiadas.

Espero que tenhamos resolvido seu problema, mas se não, pelo menos você terá um entendimento muito melhor de seu forno, o que o ajudará em seu próximo contato de serviço. Você será um cliente muito informado quando eles baterem à sua porta.

Perguntas e Respostas

Questão: Depois que o forno estiver ocioso, ele frequentemente (75%) não fornecerá calor quando o termostato fizer um pedido. O que acontece quando não funciona: - o termostato faz o pedido - o ventilador liga - o ignitor de superfície começa a brilhar, depois apaga - o ventilador continua. O remédio que funciona 100% do tempo: - desligue a chave na parte externa do forno - espere 30-60 segundos - ligue a chave - o forno funciona bem até o próximo longo período ocioso. Ideias?

Responda: Parece muito com um interruptor de pressão. Veja se isso ajuda. https: //dengarden.com/appliances/Everything-You-Ne ...

Questão: A luz vermelha em minha fornalha permanece sólida? Alguma sugestão?

Responda: Você deve ter um gráfico explicando os códigos da luz vermelha. Na minha experiência, um vermelho sólido significa que a unidade está ligada e aguardando comando.

Questão: Minha situação é que ele não vai ligar até que eu toque / puxe alguns fios e então ele funcionará enquanto eu estiver segurando, mas quando eu o solto, ele desliga e mostra códigos de erro (led piscando ) Este é apenas o módulo de controle?

Responda: Pode ser ou pode ser o próprio chicote / conector. Esses pinos / conectores às vezes se soltam e causam esse tipo de problema.

Questão: Eu pulei o interruptor de pressão porque o tubo continua se enchendo de umidade. O que causaria isso?

Responda: A ventilação inadequada é a causa mais comum de excesso de umidade. Não posso dizer o que pode ser impróprio, mas geralmente é o caso.

Questão: Meu soprador desligará no final de um ciclo de aquecimento e funcionará por mais 3 segundos. O que pode fazer com que o soprador da minha fornalha desligue?

Responda: O soprador sempre continua a funcionar até que a temperatura no trocador se esgote e atinja o limite. Isto é normal.

Questão: Eu tenho uma fornalha de ar forçado a gás Lennox 2003. O gás dispara, mas o soprador só funciona às vezes. A empresa HVAC diz que preciso de um novo forno, ou uma nova placa-mãe e interruptor de pressão de ar. Meu filho fez o teste de diagnóstico do manual e não consegue ver que preciso de mais nada do que um novo relé. Qual a sua opinião, por favor?

Responda: Eu não sei o que é um design Lennox 2003, mas se o teste mostrar que um relé de ventoinha é ruim, então eu definitivamente tentaria antes de fazer uma compra maior, já que eles não são tão caros.

Questão: Nossa fornalha foi ligada, mas não acendeu duas vezes na semana passada. Quando o reinicializamos manualmente na caixa do disjuntor, ele funciona corretamente. Alguma ideia do que poderia estar errado?

Responda: Existem algumas peças em uma fornalha que podem estar estragadas ou apenas fazendo o que deveriam fazer devido a algo acontecendo naquele momento. Um sensor de chama sujo pode ser intermitente, portanto, limpá-lo é essencial ou se tornará mais frequente. Talvez o interruptor de pressão esteja estragando ou talvez o tempo ruim tenha enviado uma corrente de ar para baixo ou através da chaminé, o que pode levar o interruptor a pensar que não está recebendo a pressão certa. Se isso acontecer mais do que algumas vezes em uma semana (assumindo que não haja ventos fortes), você pode querer substituí-lo antes que ele saia todo junto. Essas são ocorrências comuns que são fáceis de verificar ou corrigir por conta própria.

Questão: Meu forno permanecerá aceso por algo entre 30 minutos e algumas horas, mas depois desligará e mostrará um código de bloqueio. Devo limpar o sensor de chama?

Responda: Embora não faça mal tentar limpar o sensor, não tenho certeza se esse é o seu problema. Normalmente, uma unidade falha, por qualquer motivo, 3 vezes antes de travar, então eu tentaria ver o que estava acontecendo antes disso. Isso pode lhe dar uma ideia melhor de onde está ocorrendo a quebra no ciclo.

Questão: Eu tenho um A / C / forno de gás forçado Lenox, o ventilador liga, mas apenas sopra ar frio. Nós o examinamos e eles disseram que era o módulo de controle de ignição porque não estava acendendo. Substituímos essa peça e ela ainda não está brilhando. Qual mais poderia ser o problema?

Responda: O ignitor é o que eu começaria.

Questão: Por que a chama permanece acesa quando a fornalha é desligada?

Responda: Uma luz piloto (pequena chama) sempre fica acesa se é isso que você vê. Se forem os queimadores, então eu só vi isso em unidades bem antigas, mas não há informações suficientes para eu oferecer mais informações além do que não deveria, então você deveria dar uma olhada.

Questão: Acordei esta manhã com uma casa fria. Fui ao forno, desliguei, verifiquei o filtro e estava bom. Tirei a tampa para dar uma olhada na ignição quando liguei novamente. O ventilador ligou, a ignição foi ativada e eu ouvi a válvula de gás abrir, então nada. A ignição desligou e girou mais duas vezes. O forno é Goodman e emitiu um código de erro (1). Qual pode ser o problema?

Responda: Supondo que o gás esteja ligado, inicialmente verificaria o interruptor de pressão, mas há muitas possibilidades com base nas informações sem executar alguns testes.

Questão: Meu forno estava funcionando bem até este fim de semana. Liguei o termostato, liguei para aquecer. Nada! Reinicializo manualmente na caixa do disjuntor. Nada! Acabei de substituir o filtro. Quando eu chamo de aquecimento, o motor do soprador liga, a ignição NÃO acende. Testei a ignição, ela brilhava. Já limpei o sensor de chama. O que diabos poderia estar impedindo a unidade de funcionar?

Responda: Deve haver uma luz piscando na placa de circuito para informar aproximadamente onde procurar o problema. Como o soprador está funcionando imediatamente, algo falhou. Talvez a placa ou o motor indutor, já que está acontecendo antes mesmo de a unidade tentar acender.

Questão: Tenho um forno de autoignição Intertherm. Acabei de comprar a casa e o ar condicionado funciona, mas não o aquecedor. Então, comprei um novo interruptor de pressão, mas ainda não tenho ignição. Então cavei um pouco mais fundo e encontrei um ignitor realmente ruim, como cerâmica queimada e material derretido. Eu substituí isso e ainda sem aquecimento. Posso ouvir um clique como se uma válvula estivesse abrindo, e posso sentir o cheiro de gás quando isso acontece, mas o ignitor não parece ficar quente. Estou perdida. A placa de controle tem um LED vermelho constante, o que significa que o controle está ok. Como devo solucionar o problema de ignição do meu forno?

Responda: Bem, eu ia dizer placa de controle e, embora diga que está tudo bem, se não estiver, pode dizer qualquer coisa. Teste a tensão no fio de ignição para ter certeza.

Questão: Como você sabe quando sua placa de circuito em uma unidade HVAC de ar forçado está com defeito?

Responda: Normalmente, você verá potência ruim ou nenhuma potência indo do ponto A ao ponto B. No entanto, há muitos A's e B's, então você realmente precisa saber o que está testando. Existem alguns "sinalizadores" que podem dar a você a ideia de que é ruim, mas o teste elétrico é a única maneira verdadeira.

Questão: A fornalha é ligada e desligada. Com base no seu artigo, o sensor de chama está ruim. Substituí o sensor e agora o código do flash está me informando que há um problema no ignitor. Por que o ignitor acende o fogo, mas ainda apaga?

Responda: Talvez a placa seja o problema, mas não posso dizer sem fazer testes.

Questão: O acendedor de minha fornalha acende, mas as chamas não acendem. No entanto, se eu reiniciar o interruptor de energia, o forno acende e aquece a casa adequadamente por um ciclo. Um interruptor de pressão com falha permitiria que este ciclo funcionasse?

Responda: Sim, pode muito bem ser. Os interruptores de pressão podem ser "meticulosos" e nem sempre simplesmente desligam. Eles podem agir de forma engraçada e morrer às vezes.

Questão: Eu tenho um forno a gás Nordyne m1mb 070a aw. Tudo no meu termostato está funcionando bem. Meu forno está ligado a gás está ligado agora a luz vermelha na placa não está nos fios no forno estão quentes porque eles acenderam quente, mas nenhuma luz vermelha não está ligando, ou mesmo tentando funcionar. O que aconteceu?

Responda: pode ser o transformador, fusível, placa ou todos os 3.

Questão: Eu tenho uma fornalha Luxaire e quando funciona, funciona bem, mas todos os dias tenho que reiniciá-la porque o ignitor não acende. Eu já o substituí e ele substituiu ontem à noite. Recebo um pequeno ícone de chama na minha fornalha. O que poderia estar fazendo com que um ignitor novo apenas ocasionalmente não acendesse?

Responda: A ignição é alimentada pela placa, então essa é uma possibilidade, mas se ela estiver brilhando e não acender o gás, então esse é um problema diferente e tem algumas possibilidades.

Questão: Se o interruptor de pressão do meu forno estiver funcionando, mas ainda não houver faísca, o que acontecerá?

Responda: Se estiver faltando uma faísca, provavelmente será o acendedor de faísca ou o módulo de faísca. O teste precisaria ser feito para determinar isso, a menos que você apenas role os dados e substitua um e depois o outro ou ambos. Lembre-se de que não posso garantir isso, mas essas são falhas comuns que apresentam esse sintoma.

Questão: Minha fornalha depois do verão não acendeu. Meu profissional disse que era o circuito e a placa de controle. Ele o substituiu, mas a fornalha não acendeu. Simplesmente zumbia. Você tem alguma ideia?

Responda: Embora eu não possa dizer o que há de errado, posso dizer que ligaria de volta para o profissional e faria com que ele consertasse de maneira adequada.

Questão: Se a placa de circuito estiver ruim, o forno funcionará? Meu forno funciona bem às vezes, mas algumas vezes por dia, geralmente no meio da noite, ele sopra apenas ar frio. Dois técnicos me disseram que a placa de circuito está boa, mas o terceiro técnico disse que a placa de circuito está ruim. Por favor ajude!!

Responda: Uma placa pode causar coisas estranhas, uma vez que está no controle. Quando isso acontece, os fornos podem funcionar de forma intermitente. Não estou diagnosticando seu problema, entretanto. Apenas respondendo à sua pergunta que sim, uma placa ruim ainda pode permitir que o forno funcione de forma intermitente.

Questão: Minha conta de luz dobrou este mês. Minha fornalha entrará em ação e atingirá a temperatura desejada e irá clicar e parar de soprar ar quente, mas ainda está soprando. Em seguida, ele clicará novamente quando precisar aquecer novamente. Você tem uma sugestão?

Responda: Parece que a ventoinha está funcionando em tempo integral porque você a configurou para “ventoinha” ou porque há um curto causando isso. Dito isso, eu corro o meu em tempo integral e não tem muito impacto na minha conta, então talvez seu motor esteja ruim e consumindo alta amperagem.

Questão: Verifiquei o cano do telhado com uma mangueira de jardim até o rastejamento e está limpo. Também substituí o interruptor de pressão pela peça original do fabricante. O manômetro fecha a chave em 0,68 IWC e abre em 0,58, mas aqui está minha pergunta: por que não estou recebendo 24 volts depois que minha chave de pressão abre e como obtenho o suprimento necessário de 24 volts?

Responda: Você não terá 24v se não estiver pedindo calor. Você teria que tocar no lado inferior do transformador, suponho, mas prefiro que você teste a resistência.

Questão: Há energia indo para o forno, mas a luz indicadora não está funcionando. O que isto significa?

Responda: Provavelmente é um transformador ou placa ruim, mas isso não pode ser certo sem testes.

Questão: Minha unidade externa de A / C está funcionando e enviando ar frio para o forno, mas o motor do soprador interno não recebe energia. O fusível está ok e a luz está acesa. O que mais devo verificar?

Responda: Existem muitas possibilidades. Escrevi alguns outros artigos que podem ajudá-lo a restringir. É estranho se funcionou para o aquecimento e tudo mais parece estar funcionando, mas não o ventilador para o AC. Pode ser uma conexão ruim ou um problema com a placa de circuito ou estatística.

Questão: Só tive que substituir o ignitor em minha fornalha. O ignitor tem um chicote, mas a própria fornalha não. Posso conectá-lo sem o chicote e emendar os fios? Em caso afirmativo, quais fios se conectam a quais? A fornalha tem um fio preto e branco, mas o ignitor em si ambos os fios são brancos

Responda: Sim. Você pode conectá-los juntos, e não importa qual fio é qual neste caso. Apenas não conecte ambos a um ou todos juntos. (Eu provavelmente não deveria ter que dizer isso, mas você ficaria surpreso com o que tenho visto as pessoas fazerem.)

Questão: Minha fornalha não parece estar recebendo gás. Eu não sinto o cheiro. Qual poderia ser a causa disso?

Responda: Você realmente não deveria ser capaz de sentir o cheiro de gás em sua fornalha. Se você quer dizer que a linha principal está entrando, o problema está fora do forno.

Questão: Não há luz de energia ou qualquer luz saindo da minha fornalha, mas ouço um som de que quer acender, mas nada está acontecendo? O que eu posso fazer?

Responda: Parece que você tem poder para isso, mas eu verificaria isso primeiro. O zumbido é provavelmente um transformador se for um zumbido bastante suave (não um zumbido de motor). Eu verificaria o fusível na placa. Provavelmente é um fusível do tipo carro de 3 amp. Se estiver bom, eu verificaria a alimentação de e para o transformador (120v na saída 24v). Se tudo isso estiver correto, então eu estaria inclinado a pensar que o quadro é ruim, mas não posso realmente confirmar isso sem estar lá.

Questão: Eu tenho uma fornalha com o ignitor de faísca e o piloto não acende. Se eu acender manualmente (papel leve e colocado na frente do piloto) os queimadores irão acender e o forno funcionará por 20 minutos e então desligará antes de atingir a temperatura ajustada. Se eu apenas tento ligar o forno sem interferência manual, o indutor é ligado, ouço um clique, mas não vejo uma faísca no ignitor ou ouço vários cliques. O módulo piloto é provavelmente o problema e, em caso afirmativo, como você testa o módulo?

Responda: Você testa para ver se o acendedor de faísca está recebendo a voltagem adequada da placa. Se não, é a placa e, se sim, é o próprio sparker.

Questão: Eu tenho um forno a gás de 2 estágios de alta eficiência de fluxo ascendente Rheem 2009. Faz parte da série GRM, modelo # RGRM-07EAMES. O motor do soprador parou de funcionar. Tem um motor GE ECM 2.3, Repl. # 51-24374-28. Todos os fios estão em boas condições, sem curtos ou fios quebrados. O fusível na placa principal está OK. Tirei o módulo do motor do soprador. O fusível de 2 A "funcionou" na placa de circuito queimou. O que causaria isso? Seria outro componente do módulo do motor? Posso soldar um fusível de 2,0 A no local da placa de circuito impresso?

Responda: Não posso dizer honestamente, porque não é um reparo que eu já tentei ou me pediram para fazer. Uma coisa que posso dizer é que, se a unidade foi registrada, você ainda deve estar na garantia. Antes de passar por tudo isso, eu acessaria o site de garantia de Rheem e executaria o número de série. Um novo módulo seria melhor não apenas para resolver o fusível, mas também para o problema subjacente que o causou, porque eu também sei que a grande maioria dos motores nunca falha, mas os módulos sim.

Questão: Tenho um forno Miller modelo # M7RL 072A AW. O motor indutor funciona excessivamente, o gabinete interno está muito quente e o forno não acende. O sensor de temperatura não permitiria a ignição se a temperatura na área do painel de controle fosse mais quente do que o normal?

Responda: Se a chave de limite superior foi desarmada, então sim, o soprador funcionaria até que a temperatura caísse para a faixa permitida e então tentaria disparar novamente.

Questão: Minha unidade liga, mas o ventilador não liga a menos que eu ligue manualmente, então ele funciona bem até que o forno desligue e ligue novamente. Então eu tenho que dar uma ajuda no ventilador novamente, será que o motor do ventilador está sujo e só precisa ser limpo?

Responda: Espero que você esteja usando algo além da mão para fazer isso, mas soa como o capacitor, se é o que está acontecendo. Na maioria das vezes montado na parte frontal da caixa do ventilador.

Questão: As velas incandescentes são iguais às do ignitor? Não há nenhum som de clique e as chamas não se acendem.

Responda: Você pode ter um problema com o interruptor de pressão. Veja se este artigo pode ajudar a ver. https: //hubpages.com/home-improvement/Everything-Y ...

Questão: Eu tenho uma fornalha Gilbert e o indutor funciona. A ignição brilha intensamente. A válvula de gás não ligou para produzir uma chama quando estava frio lá fora, como zero. O sensor de chama detecta que o dispositivo de ignição de superfície quente está quente? Ou alguma outra coisa liga a válvula de gás?

Responda: Grande detalhamento de informações! Então, tudo que posso fazer é restringir, mas é assim que devo proceder. Primeiro suspeito, interruptor de pressão. Você pode testar com um voltímetro para ter certeza de que está fechando assim que o dispositivo de ignição começar a brilhar. Ou pulando para fora e ver se ele dispara. Se não, verifique se há bloqueio de combustão e ouça o indutor para ver se está soando lento ou algo lá dentro. Caso contrário, pode ser válvula de gás. Teste se a voltagem está chegando. Se não, suspeito do conselho. Lembre-se de que isso é apenas um processo, não um diagnóstico. Um voltímetro e conhecimento do que você está fazendo com ele são importantes. SER SEGURO! Não faça nada com que você não se sinta confortável.

Questão: Em um forno portador, o que quatro luzes verdes piscantes e duas luzes amarelas piscantes indicam?

Responda: Deve haver um gráfico de código em uma das portas do forno ou no manual de instalação que informa o que isso significa. Nem todas as marcas e unidades são iguais, então, sinto muito, não sei de primeira mão o que ele está tentando dizer a vocês.

Questão: Por que meu soprador está funcionando quando o T-stat está desligado?

Responda: Se estiver tudo desligado, então você deve ter um curto no fio de estatística.

Questão: Por que a fornalha começou a fazer barulho de batidas e a cheirar a secador de cabelo?

Responda: Meu pensamento inicial é o motor do ventilador ou a roda do ventilador. Eu inspecionaria visualmente essa área para ter certeza de que nada foi sugado pelo ventilador e que a roda do ventilador não está quebrada / balançando / esfregando. Certifique-se de desligar a alimentação da unidade antes de colocar as mãos nela.

Questão: Por que meu aquecedor sopra ar frio?

Responda: Algo falhou e o soprador está funcionando como padrão, provavelmente.

Questão: Como posso saber se a válvula de gás está ligada ou não? O interruptor tem que estar para cima e para baixo ou lateralmente?

Responda: Se a manopla da válvula estiver "alinhada" com a tubulação, ela está aberta / ligada. Se for virado lateralmente na direção do tubo, ele é fechado / desligado.

Questão: Meu forno Comformaker está mostrando um código de quatro flashes. Troquei o interruptor de limite. Por que não está acendendo?

Responda: Não sei o que significa o código de quatro flashes, pois os códigos variam por marca. O interruptor de pressão apenas confirma que o indutor está ventilando corretamente. Só porque o código flash (se dissesse interruptor de pressão) diz interruptor de pressão, não significa que o interruptor está ruim, apenas que é por isso que ele não deixa o forno acender. Então, pode estar ruim (o que parece que não estava desde que você o substituiu) ou pode ser um bloqueio na chaminé, o motor está ou está indo mal, e algumas outras possibilidades menos prováveis. O teste elétrico do circuito pode ajudar se você souber como usar um voltímetro e executar esses testes para ajudar a confirmar qual é exatamente o problema.

Questão: Minha fornalha parou de funcionar. O motor do soprador está tentando dar partida (lentamente). Sem chama ou ignição. Seria o capacitor?

Responda: O forno deve funcionar corretamente até o ponto de o soprador ligar antes da falha, então se o capacitor estiver ruim, não acho que seja o único problema.

Questão: Eu adicionei um AC a um forno há dois meses, mas agora o aquecimento não está funcionando. Qual poderia ser o problema?

Responda: Pode haver um monte de coisas, mas presumindo que o forno funcionou bem antes e o ar-condicionado funcionou corretamente e nenhuma outra mudança foi feita, eu não sei como explicar. Um bloqueio teria afetado o A / C também. Talvez eles tenham alterado a configuração de velocidade do ventilador ao colocá-lo.

Questão: O ignitor da minha fornalha acende, mas não parece estar acendendo. Qual pode ser o problema?

Responda: Se o seu forno está piscando um código, compare-o com o gráfico no manual do usuário (você pode encontrar isso online) ou, provavelmente há um gráfico no forno para dizer o que os diferentes códigos significam.

Questão: A luz de status em meu forno Intertherm não está acendendo. Tenho energia indo para a placa de circuito, mas parece que não há energia indo para o motor do soprador ou qualquer outro lugar. Qual pode ser o problema?

Responda: Ele pode ter um transformador queimado, ou talvez o pequeno fusível de três amperes que geralmente está na placa possa ter queimado. Você pode ver facilmente se o fusível está queimado apenas removendo-o e olhando para ele.

Questão: Eu tenho uma unidade portadora. No meio da noite, ele parou. Eu tenho uma luz amarela piscando, não vermelha. Se eu ligar o ventilador, ele funciona. Portanto, está obtendo energia. Qual pode ser o problema?

Responda: Pode ter sido um golpe de sorte, se não for uma ocorrência regular. Isso às vezes acontece.

Questão: A chama acende-se por um minuto e depois apaga-se. Substituí o sensor de chama e o ignitor, mas ainda faz a mesma coisa. Isso é com válvula inteligente honeywell. Alguma sugestão sobre o que pode causar isso?

Responda: Bem, já que você substituiu o sensor, eu verificaria o limite máximo ou a placa. Talvez um deles seja o culpado. Eu precisaria fazer testes elétricos para confirmar.

Questão: Eu tenho um gás HE Lennox 92AF1UH que parece estar vazando do coletor de umidade do escapamento (não é o termo técnico). Quando o abrimos inicialmente, o filtro estava completamente encharcado e mofado. Limpamos as mangueiras e secamos tudo, mas ainda há umidade se acumulando após a operação. A unidade tem cinco anos. Alguma ideia?

Responda: Embora seja difícil rastrear a origem / problema da água pela Internet, posso dizer que um Lennox de 5 anos ainda pode ter garantia de peças, portanto, se você conseguir um técnico, talvez só precise pagar mão de obra. Seu trocador de calor definitivamente tem garantia se for esse o problema.

Questão: I had replaced the ignitor switch in the furnace in the winter. Now, we are using the A/C and the blower is continually running in OFF/ON/Auto and the electronic ignitor is trying to light. I thought the blower problem was a Relay/Limit Switch, but would that also cause the ignitor to spark constantly?

Responda: There has to be something wrong with the wiring or the circuit board is shot. There is no other way a furnace would try to fire when in a/c mode. The fact that the blower is running full time regardless of mode tells me it's more likely the board.

Questão: Our furnace will run, and after a few minutes the thermostat shuts off, comes back on, and a few minutes the furnace will shut off and then back on. My thermostat is connected to the C on the mainland, so I know the circuit board is restarting. Top of core looks fine, but I can't figure out if my secondary is cracked? It was installed in 2001.

Responda: I would need to run some tests to figure out why your unit is kicking off and on or witness what part of the cycle it's stopping. As for the heat exchanger, you'd probably need to have someone run a smoke or CO detection test and you're likely still to be under a parts warranty. Get a CO detector to be safe.

Questão: I have a Payne furnace which is no longer firing. The igniter relay is fine and the ignitor is glowing bright orange, but I get no voltage at the gas thermocouple solenoids, expecting 24vac but nothing, so no gas flows and no fire. Am I looking at a main board failure for my furnace or is there a sensor that might prevent the board from putting out voltage?

Responda: I would take a look at the pressure switch first. It can cause this type of behavior.

© 2014 Dan Reed

Phyllis Celli on July 09, 2020:

You have an excellent questions & Answers page!!! I live in an apartment complex and my heating system is right in the middle of our living space, etc, This heater/air-conditioner is so very very loud & disturbing - Other than reporting to Maintenance, it was stated that these P&N WeatherKing Heaters are Loud. I BEG you to please help/aide me-it is extremely bothersome - other units like mine are the same.....Kindly comment and make suggestion!!!! THANK. YOU

Charisse Anderson-Wolfe on June 18, 2020:

I have no power to my furnace or thermostat? My ac wasn’t working and my husband put in basically all new parts, now the thermostat won’t come on and nothing happens. He put a new control module on the heat, because the tech said it was going out last winter. Don’t know what to do? No power to our Coleman Forced Air Furnace. Please help!!!

Kay Baker. M on March 01, 2020:

My furnace is clicking on but the auto fan does. Not come on

Mike L em 17 de janeiro de 2020:

"My Goodman gas furnace blows a fuse as soon as the burner lights. What would cause this?"

Has there been any feedback from the original question, my goodman is doing the same thing, and if not where would be a likely place to start 1st, any suggestions would be very helpful.

Dominic on October 15, 2019:

Hi i have a goodman its flashing red light. 4 flashes what does it mean

TIM OCONNELL on October 02, 2019:

If have power coming out of the on off switch on my furnace and the 5 amp fuse is still good, why wont the green indicator light come on? Furnace acts like its dead.

Robert Estrada on August 10, 2019:

I have a old ruud unit 1994 and i the light that says power is not on. I tried looking for fuse but it dosen't seem to have one. I have no power going to the circuit board. It was running earlier but sounded like it was struggling then turned off. I checked breaker and nothing.

Je on June 03, 2019:

I have a new furnace and the inducer will kick on and off while in cool mode

Chuck on May 18, 2019:

My problem is when I went to start.my air for the first time this season,not sure what happened nut now no furnce and the air did not come on, would appreciate and input, Thanks..

Brett Winter on May 16, 2019:

I recently added an a/c to my gas furnace. When I hooked up the extra wires for the a/c, the furnace would no longer work for heating. The small fan kicks in and the furnace lights but then the burner trips and the big furnace fan starts up. If I disconnect the a/c wires the furnace works fine again

James on May 07, 2019:

Thermostat seems to be working fine. Turn heater on but no glow on the ignitor. Checked ignitor seems ok. Fan constantly runs but nothing else happens. I'm stumped

Gioia Smith on May 03, 2019:

I'm trying to find out how to thermostat is staying on 88° red lights are flashing on the side how do I get is turned off

Sherri em 24 de fevereiro de 2019:

Thank you for posting this and allowing us in on your valuable experiences and expertise. I think it has helped us fix the problem on a Sunday as well as calling a local HVAC guy! We appreciate your help via Internet!! God bless!

Eric L on January 29, 2019:

Hi, Dan. Thanks for your straight-forward troubleshooting tips - they are VERY helpful. I've run into an issue on our furnace (model Nordyne G6RA120C-20) where the red light says the "pressure switch stuck closed", not open. There are no blockages in our flu, I replaced the filter (just in case), cleaned the flame sensor (for good measure), and removed the pressure switch to see if it was obstructed or visibly stuck in some way (9300-V-0.55-DEACT-N/O-VS). I could hear the mechanism inside moving, hooked it back up, and it worked once for about 10 minutes. Now it's back to the same routine - vent motor comes on, click, ignitor comes on, click, ignitor goes off, red light flashes the "pressure sensor stuck closed" error, and tries again a few times. We have a very dry basement and I don't think it has to do with water, but I'm guessing the pressure switch is bad. Any thoughts on a "stuck closed" error like this?

Ray on January 07, 2019:

I have a goodman up draft air & heat sys , what is going on is I set the temp like at 72 the heater comes on and runs for about 10 to 13 min and the temp on the thermostat reads 72 the sys shuts off then I can hear the vent blower come on as soon as everything had turned off it runs and then the burners come back on again and everything runs again for about 10 min.Is this normal I don't think it dose it every time like this but a few times it dose and even it cycles 3 times and runs for about 10 min. I have a nest thermostat dose it have something to do with the way that type of thermostat acts ?

Nick P on December 22, 2018:

I have a variable speed 2 stage AS furnace. Lately I haven't heard the furnace kick into the 2nd stage. I tried to test it by setting the thermostat higher about 15 degrees and waited almost a half hour and it never kicked into stage 2. It remained on low flame stage 1. Can there be something preventing the furnace from kicking into the 2nd Stage?

Dan Reed (autor) on December 04, 2018:

SG - While I can't say for sure without being there and testing, a blown transformer could be the issue. Since it's pretty cheap, it might be worth trying before saying it's the board. Really, you should run some tests with a voltmeter to pinpoint the problem and avoid spending money that you might not need to.

SG on December 03, 2018:

I have a Goodman GPG1360140M41AD. It was working fine and then it blew the 3amp fuse on the control board. I checked all the wires and replaced the thermostat and replaced the wire from the thermostat to the furnace. It first began to recycle and not ignite and now it blows the fuse once it tries to ignite. So it was not the thermostat. Can a dirty flame sensor cause this issue or should I replace the control board.

Dan Reed (autor) on November 26, 2018:

Thank you Mark! I really appreciate the feedback. I take a beating sometimes from guys who feel I'm taking business away from them and well, I suppose I do, but my intent is to help those who can't afford to pay $150 or more to come clean a flame sensor. While I don't intend to take work from people my loyalty is to those who want to be warm and not at the cost of their family's Christmas when the fix is simple. I'm glad you see that. I hope this and other articles never have to come in handy for you but if they do, I'm glad I can help. Best wishes to you and yours.

Mark J on November 25, 2018:

Dan - you, and guys like you, that post basic knowledge like this are freakin' awesome. I can't tell you how much it is appreciated from a layperson's (non-HVAC technician) perspective. I'm more that happy to get on a professional's schedule and pay them to come out and fix an issue - but your type of posting really helps to cut down on the "duh" service calls - and that is extraordinarily helpful. Thank you sir.

Dan Reed (autor) on October 24, 2018:

Rich - The pressure switch clicking when you blow/suck on the tube doesn't mean it is working properly. It does sound like that may be the issue still.

Rich A on October 23, 2018:

Dan- My furnace is attempting to start the motor starts for about thirty seconds and shuts off. I checked the pressure sensor manually by blowing into the hose and can hear it opening. The furnace itself is giving code of "Pressure switch stuck open". It's my understanding often times you get a pressure switch error but the problem is other components. The ignitor does not appear to light whatsoever, I hear no clicking, smell no gas. As far as I can tell there is no obstructions in the flue. Any ideas? Im guessing the ignitor or flame sensor could be faulty.

Dan Reed (autor) on October 23, 2018:

Jenn - While I can't be sure of the issue it does sound like a pricey repair for a 17 year old furnace. $1000 is a nice down payment on a new unit and there is no repair I can think of that would cost that much unless it was to replace a heat exchanger (which again, I would rather do a furnace for that money) or a complete overhaul of the parts there which makes me leery that he doesn't know what the problem is so just decides to replace everything. Sadly, these "part changers" are out there. Please get a 2nd opinion.

Jenn Alb on October 22, 2018:

We have a natural gas forced air furnace-17 years old. When I turn it on, it will light, heat, and blow hot air until it hits temperature and shuts off. When the temperature drops a degree and it should go back on and heat, it will click back on--it will click to start, you can hear it trying to go-then it does not light. The blower goes on anyway and begins to blow cold air into the house--which then makes the thermostat temp drop and it just stays on blowing cold. In order to get it to work again-I have to shut it off at the thermostat, wait at least 90 minutes or so, and then turn it back on. It heats nicely--will superheat to 78 degrees if I let it (we did this last winter to give more time with it off on cold days). HVAC told us $1000 to fix--but I think that can't be right since it still works fine--I am thinking gas valve or thermocouple. My husband is handy, rebuilt outside air conditioner, replaced anode rod in water heater, replaced fan on water heater, etc... but afraid of messing with gas esp. since my son's bedroom is in basement near furnace.

Any suggestions Does that sound like a rip-off for repair?

Obrigado!

Dan Reed (autor) on September 28, 2018:

Penny - If the stat is off then you shouldn't have heat but is the fan set to "on"? That would allow the fan to just simply run like a fan and only call for heat/cool when necessary. If everything at the stat is off then you must have a short circuit somewhere in the stat wiring or control board. You may need a tech to do electrical tests to be sure.

Dan Reed (autor) on September 28, 2018:

Tracy - While I'm not sure what the cause is, it's not normal and likely not the blower's fault but something else causing it. Bad voltage, filters not being changed regularly, improper duct size starving the motor for air...there are a lot of possible causes but this is what I'd be checking for.

Penny Escalante on September 27, 2018:

My furnace blower is running but not blowing out heat, my thermostat is off, what do I do?

Tracy G on September 27, 2018:

Hi Dan, We have replaced the blower on our gas furnace the last two years. After it is replaced, it works fine for the rest of the winter, then when we try to use the furnace come the next winter it won't work again. This will be the third year we will have replaced the blower. Any idea why this would happen?

Dan Reed (autor) on September 23, 2018:

Brad W - Unfortunately there isn't enough information for me to help. Maybe the stat is bad? Maybe a limit? Desculpe.

Brad W on September 22, 2018:

Hi Dan, I have a forced air coleman furnace that only works when the thermostat is turned all the way up and only runs for a few minutes and only blows warm air, any ideas on the reason? thank you

Dan Reed (autor) on September 11, 2018:

Tammy - I'm betting that it's the igniter. When you here the clicking that is the spark ignition trying to light....do you see a tiny spark? If you do, then the problem is either the gas valve not opening or the gas is off or potentially there is air in the line and it may need bled out. These are just guesses of course but all things I would be looking at if I were there.

Tammy on September 10, 2018:

I turned my furnace on for the first time since winter it worked fine in the winter but now wont turn on. I hear it clicking trying to light but doesnt. What could be wrong??

Dan Reed (autor) on August 28, 2018:

RAur - Thank you for the feedback. I think it's a little high but I'm in the "Heartland" so perhaps that's reasonable for the west coast. I wrote an article about cleaning the flame sensor...I hate to say it may have just been dirty. These usually fail or they don't...they don't usually act erratically unless they need cleaned. If they fail, they just fail. No resetting will help it. I have to clean mine every year.

RAur on August 27, 2018:

Dan, I got my furnace fixed, but needed a tech/service call. Essentially, it came down to the flame sensor being old and needing to be replaced. It was functioning erratically with no consistency. Manually recycling the power was helping, but with that i was was getting lucky with it working at times and not at other times. The tech replaced the flame sensor. The visit and the flame sensor together cost me ~$300/-. I am not sure if that is expected. I live the pacific northwest close to Seattle.

Dan Reed (autor) on August 27, 2018:

RAur - You're welcome. I do have other articles here that may help you find where the fault is occurring if you check on my profile page, you'll see the list and can determine if one may be helpful.

Dan Reed (autor) on August 27, 2018:

Anna,

It sounds as if you have a short in the low voltage wiring, stat, or at the board. You're correct. If you have it set for a/c you shouldn't be getting any sort of call for heat.

RAur on August 26, 2018:

Dan, thanks for your response. Your explanation makes sense, at least is logical. In terms of the fault that might be occurring, I will read a bit more to understand how i would find it. I will call for a service technician soon. When I get it resolved, i will revert back to this thread, so it might be beneficial to other readers of your site and for search engine indexing.

Anna on August 26, 2018:

Our furnace is not on but is glowing like it wants to ignite. We have the air on so it should not even be trying to light.

Dan Reed (autor) on August 26, 2018:

RAur, I'm sorry but there are too many possibilities for me to try and narrow down based on the given information. It sounds like a fault is occurring and when you reset the power you're resetting the unit, clearing the code and the unit is running until the fault happens again and you're back to square one. What the fault is, I couldn't say without running tests or observing where the unit is shutting down in the cycle.

RAur on August 26, 2018:

Dan, I have a nest thermostat and an older furnace. They have been working well. But now the furnace (fan or heat) is not turning on even when i set the temperature on the thermostat higher than the temperature at home. However, i am able to get the fan and heat going when i manually turn off and then turn on the furnace's electrical switch. Any thoughts? Obrigado.

Dan Reed (autor) on August 15, 2018:

It sounds like you have an older furnace so there aren't too many parts there. It could be the limit or gas valve going/gone bad. I don't have enough info here to say for sure but that's what I'd be looking at.

Joe Moore on August 14, 2018:

Hi my furnace is gas, the blower turns on in the summer to cool itself. The pilot lights and stays lit. Last winter my furnace wouldn't kick on to blow heat when my thermostat was reading a significant drop in temp. It stopped heating my house. That part hasn't worked since. Any suggestions?

Dan Reed (autor) em 31 de maio de 2018:

Jordan beyer - If it's frying the breaker then you have an electrical issue that I am not sure what to offer as a cause. Bad wire? Bad breaker? If it's just tripping the breaker however then something in the unit is trying to draw too much power thus would short the board and then trip the breaker.

Jordan beyer em 31 de maio de 2018:

My circuit board keeps getting fried and the breaker not sure why any thoughts

Dan Reed (autor) em 16 de maio de 2018:

E Thomas - It very well could be. When there are funky readings and weird activities that just don't seem to tie together for logical conclusion, the board is a pretty regular suspect.

E Thomas on May 15, 2018:

I have an issue with m HVAC unit where the blower runs non-stop, but the AC (or the furnace) wouldn't turn on. I have made sure the thermostat is fine. On the control board, there is no voltage between R and C. The fault LED is flashing an error - Open RO Switch. I have confirmed that that the RO switch circuit is closed. Could this be a bad board?

Dan Reed (autor) on May 08, 2018:

I really can't say exactly what is happening but if it started with the new exchanger they should be fixing or at least figuring out what the issue is for you. I know propane at the wrong pressures can produce soot...perhaps it was wrong before he came but a bad exchanger had covered that up somehow? Do you know for sure that the unit was converted to LP? Units almost always come set up for gas and then need an LP conversion kit to make it work with LP which means changing out the orifice and valve spring as well as balancing the gas pressure to whatever the unit requires. If these things aren't done it will have your unit all goofed up.

Phil em 07 de maio de 2018:

Hi, last February I had a Heat exchanger replaced in my Miller Propane Furnace. The Furnace starts ok to where ever the thermostate is set for, The problem i am having, is the furnace is turning off and on about every minute about 10 times before staying off. The roof vent is completely covered in black soot and it is all over the roof, None of this occured before the tech changed the heat exchanger. What could be the problem?

Dan Reed (autor) em 02 de maio de 2018:

Jerry - I cannot say for you to do that. I do not have enough info to recommend you do anything with those wires other than what they're intended for. If the problem is new then the wires are not likely the issue. Kill the breaker to make the unit stop.

jerry em 02 de maio de 2018:

is there any way i can unhook them to wires and run them some where else to see if the unit will shut down or not with just them two wires?the unit only has heat hook to it.

Dan Reed (autor) em 02 de maio de 2018:

Jerry - I would imagine the green is hooked to the white terminal then those 2 wires would give you heat but they may have used a device call "add a wire" and then it may be all they needed to do the a/c when that was installed as opposed to pulling new wire. That is my guess.

jerry on May 01, 2018:

all the wires on the honeywell digial thermostate are attached didnt hook them up myself but where it comes into the wall to th pigtail plug wiring harness there is only two wires hooked up a red and i believe a green one and all others where cut short there

Dan Reed (autor) on May 01, 2018:

Jerry - I don't believe the stat is faulty since there would be other features that would shut down the unit if it overheated and if it won't shut off then it sounds like something is mis-wired perhaps.

jerry em 30 de abril de 2018:

have an intertherm electric furnace hooked the power up to it set the thermastate and it was all ready running waiting for it to turn off at th temp i set it but it never shut off and the blow was still running on hight and i could see the coils still glowing red tryed everything to shut it down till i pulls the disconnect over the cartages fuses and it shut down could it be the digital thermastate being faulty?

Dan Reed (autor) em 30 de abril de 2018:

Mrs. Klann - While I can't say what's causing this I can say that the unit should be shutting off then because if the flames run without the blower it will overheat and shutdown. If that isn't happening then I would quit running it because it could become a safety hazard. You'll need to call a technician however to find out what's the cause of this. Maybe a bad limit switch or circuit board but again, I can't say for sure based on this little bit of information and not testing the circuit.

Mrs.Klann on April 29, 2018:

My furance flames come on-but blower wont run-unless I keep turning it on by thermostat switch??

Dan Reed (autor) on April 24, 2018:

Jesse - The answer to this all depends on your mechanical abilities. For someone who is familiar with taking things apart and putting them back together I'd say yes, it's a pretty easy task. If you're not, then it could be more hassle and lead to more cost than it's worth. If you do, don't forget to buy a new capacitor with your new motor. Boa sorte!

Jesse on April 24, 2018:

I think I have a blower that is starting to fail. Last year I could hear it making a squeaking sound but would always come on. Now it won't come on and the red light is blinking.

Is replacing a blower easy or should I get an HVAC tech?

Dan Reed (autor) on April 10, 2018:

Shawn - it could be so many things. Try and catch the code it blinks if you have that LED on your unit next time it breaks down. That would help narrow it down. If not, he really should call a tech for you.

Dan Reed (autor) on March 19, 2018:

Bill - I'm not sure what would cause both the fuse to blow and then when that's replaced still not run. Being brand new, I would certainly call the installer and ask them to come figure out and fix the issue.

Bill on March 18, 2018:

I have a airtemp gas furnace brand new it ran all night on and off only ran 5 min then went off got up this morning nothing found a blown fuse on the board replaced fuse now ignitor glows but will not light

Mollie em 16 de março de 2018:

I have an intertherm furnace, the thermostat died, changed the batteries and it works but the heater won't come on, the diagnostic light shows no problem, I turned off the switch and restarted it and nothing

Dan Reed (autor) em 26 de fevereiro de 2018:

Joe, Did you resolve the issue at the thermostat? Just turning it off and on may not have solved the problem. Otherwise, without more information or personally running tests, I'd have a hard time offering any sound advice.

Joe em 26 de fevereiro de 2018:

I have a Lennix G27M 4–100a-2 and is turning on every 10 minutes and working for approximately eight minutes and shutting down, this is after finding out that the thermostat was not working properly and I turned off the thermostat and turned it back on, what's going on please help and thank you

Dan Reed (autor) on February 23, 2018:

If the igniter is coming on but not lighting then the gas valve isn't opening. That could be because the pressure switch isn't being satisfied or it is failing. If the igniter itself isn't working then you'd have to replace it. I've written other articles that may help you narrow down your problem and perhaps make the repair.

Kami on February 22, 2018:

Hello, my furnace was coming on and cycling about 5or 10 sec. mais tarde. I cleaned the flame sensor and now nothing. the ignitor switch now coming on slower than usual and now the flames aren't coming on. it just shuts back down,

Dan Reed (autor) on January 27, 2018:

Perhaps a burnt out heating element? Definitely an issue though since if there's an odor like an electrical burn then something is shorting out and I'd have a tech come sooner than later.

Me on January 26, 2018:

We have a Coleman electric furnace and it clicks like it’s turning on but it’s not actually kicking on to blow air...and it smells like something is burning when it’s trying to click on

Dan Reed (autor) on January 21, 2018:

It's possible and if so then make sure you get stainless steel burners since you have LP...they'll last longer.

Darlene Statz em 20 de janeiro de 2018:

I have a 14 year old Rheem outdoor combination propane furnace/ electric air. In the last six weeks or so, on 3 or 4 occasions when I got up in the morning my house felt cold. When I looked at the temperature on the thermostat it read 61 when it was set at 68. After I turned the heat off and on, it went back to working fine until the next incident. The repairman says it needs a new burner. This does not make sense to me. O que você acha?

Dan Reed (autor) on January 17, 2018:

You should have a chart on your furnace that answers that for you. I do not have these memorized. Every brand and unit has it's own coding.

Dan Reed (autor) on January 17, 2018:

If the heat strips are working too hard then the breaker trips. For some reason the amperage is spiking and therefore it's working to hard, there's a short, or there's bad voltage. You need to know what is overloading the circuit. Probably a bad element or going bad. Too much resistance and/or heat due to bad amperage causing breaker to trip.

Rose on January 17, 2018:

My electric furnace blows hot air for about an hour and then the furnace breaker trips and it starts to blow cold air. The house breaker is fine. It's the breaker on the furnace that keeps tripping. What could it be?

Travis on January 16, 2018:

I have an amana furnace and its flashing a red light 6 times

Sanjay on January 06, 2018:

SO SO Helpful!! THANK YOU

Ryan on January 06, 2018:

Hello, my furnace is showing a 4 red light error indicating the high limit switch has opened. When the tech arrived he saw the error and tested the switch. According to his test the switch was closed (though the 4 red light error continued to show). He examined the rest of the unit and found that the capacitor was starting to fail (he replaced it). Within a half hour of his departure the 4 red light error appeared again. He believes that it is the circuit board that is the issue. Unfortunately for me he had a few other jobs to deal with before returning to me. He told me to reset the furnace (turn off and on) and remove the access panel to further reduce the heat build up. Since doing this the furnace has run fine.

My question is, does this appear to be a circuit board issue? The furnace has been professionally cleaned very recently (last week) and the filters are brand new. Any insight would be greatly appreciated.

Dan Reed (autor) em 02 de janeiro de 2018:

Cj - I'm sorry but there just isn't enough here for me to offer any real sound advice.

Dan Reed (autor) em 02 de janeiro de 2018:

TD - I really can't say from here. You'd have to run tests to see if that's the cause.

TD em 02 de janeiro de 2018:

My nest was not getting enough power so I used extra wire to hook common to thermostat. Then a couple days later the nest says no power from R. The furnace board has green light. I tried removing the common wire I had connected before and still no power from R. So I'm not if what I had done before caused this new problem. Anyway I took the extra wire I had used for common and connected that to R on the board and R on thermostat. Now furnace works however fan will not turn off and I have to keep recharging my nest with USB every day. Is there something wrong with the board or do you think it's the thermostat?

Cj on January 01, 2018:

Furnace stopped working in the middle of the night, turned it off, turned it back on, nothing. Went into the garage and unplugged it, then plugged it back in while it was on and it began blowing air. Flames never came on, but the furnace continues to blow air. I removed the cover for the circuit board and checked the red light on it after turning the furnace on, the light stayed a constant red. I conducted the jumper wire test which resulted in the thermostat not being the problem. I am stumped, because I replaced almost every part on the furnace within the past 5 year's.

Dan Reed (autor) on December 30, 2017:

Jose - There is not enough information here for me to offer advice. I've written quite a few articles that you could read and see if you can narrow down the possibilities a bit.

Dan Reed (autor) on December 30, 2017:

Shirley - I can't offer any advice based on this. I would really need to physically inspect the unit for a stuck open damper, back draft, or something of that nature.

Dan Reed (autor) on December 30, 2017:

Ian - Check your filter and if the a/c coil is clogged you could be trapping too much heat in the plenum. Or the limit switch itself could be bad. These are where I would start.

Jose on December 29, 2017:

I have a rudd force air furnace heater..thats warm up a little then wont start back again unless i switch button to off to heat again..cant find where filter is located

Shirley tait em 27 de dezembro de 2017:

I have a free standing gas fireplace .Will start is and it may work real good for a couple days .Then all of a sudden I look and blue flames are dancing all around in a swirl .I get scared and turn it off ,

Ian on December 26, 2017:

My Lennox SLP98 modulating furnace has a red blinking decimal light when on idle mode but it gives an E250 error code( Limit switch circuit open - check why limit is tripping, overfired, low air flow) when it fires up. How do I fix this fault?

obrigado

Dan Reed (autor) on December 26, 2017:

van - Well the ignitor is good but beyond that I cannot offer any advice based on this information. Desculpe.

van on December 25, 2017:

my older carrier gas furnace ignitor glow but the won't turn on

Pamelarenae on December 20, 2017:

Thank you so much for your help. We will contact landlord again and send letter addressing also.. Merry Christmas

Dan Reed (autor) on December 20, 2017:

Pamelarenae - I wish I could offer more help and given what you've told me I would say there is definitely an issue and the landlord MUST have someone come back if it's "black as coal" because it's not normal or healthy if it's spewing it all over the home. There would definitely be an issue that needs addressed under those circumstances and by law, the landlord must address the issue.

Pamelarenae on December 20, 2017:

Its natural gas and he does not believe duct work has been done. He said " The unusual amount of dust that I was getting was actually not dust, it was soot that the furnace has been spewing all over the house" ..the filter is black has coal. Landlord will not send her contrator back out, plus contractor only speaks russian n sasly my friend does not know russian to ask questions. Landlord said in spring she will have ducts cleaned.. it is 2 story townhome, furnace is in basement not in same room with washer dryer if that helps.

Pamelarenae on December 19, 2017:

Thanks for answering question above.. im waiting to gear back from friend. I know he has natural gas and has commented on how dirty everything gets in his home very fast. Ill write again after he responds to my text. My friend moved in about time furnace was put in so im not sure he will know alot about past duct work. Thank you again.

Dan Reed (autor) on December 14, 2017:

Elisabeth - I'm not sure what "steady on" means for your particular furnace. There should be a code chart that says if that means "normal operation" or a particular failure. Is it lighting? If so, then I'm not sure how you'd have cold air. I know that sometimes air can perhaps feel colder than it actually is but if there is a flame in the unit, I assure you it's not as cold as you might think unless for some reason your a/c and heat are coming on together. (Don't laugh...I've seen it before.) Sorry I can't be of much more help based on the information you've provided. There are just too many possibilities to narrow it down based on this. Obrigado por ler.

Elisabeth Maynard on December 13, 2017:

My furnace pilot light is on, red light and yellow light are steady on but I'm get nothing but cold air. I've checked the filter and everything else I can think of. My formate is a Nordyne model # M1MB 070A BW. PLEASE HELP

Dan Reed (autor) on December 08, 2017:

Dave - I answered the other question but here there are a lot of moving parts and I'm not sure what you're dealing with. If the fire is on, the air cannot be cold. If the furnace is failing, then the blower will come on as a default and then yes, you would have cold air but after 3 times, it should go into lock out. After all you've done, I would recommend having a tech look into this since it will likely require some tests that I cannot run from here. Eu sinto Muito.

Dan Reed (autor) on December 08, 2017:

Ryu8 - Glad to hear!

Ryu8 on December 07, 2017:

Problem fixed. Muito obrigado.

Dave on December 05, 2017:

I have HVAC furnace model number KG6RC 080C-12B. I was experiencing problems where the inducer motor would kick on but after 1-3 minutes turn off. The LED on the board had two flashes which indicated "inducer motor on with pressure switch open." After hours of troubleshooting which included removing tubes from pressure switch and making sure obstructing. Checking for obstruction in exhaust pipe and running shop vac through each end, cleaning out condense tubes I still had two flashes. I finally removed tube from pressure switch to combustion box and ran heat cycle and it worked.however during that cycle warm air would only blow for 15-30 seconds and then blow just cool air. Once I reconnected the tube it would go back to the two flashes. I noticed some grime and residue below the inducer motor so I removed it and noticed the plastic gasket was cracked and brittle. I removed the gasket it fell apart once I touched it, cleaned up the area and reseated with high temp silicone sealent . I no longer get the two flashes and the furnace runs through it's normal cycle BUT I still have a problem where the furnace is only pushing out cool air. The flames do not stay on long at all. I did remove the flame sensor and cleaned it but I fear I may have cleaned it too much by way of over use of sand paper.

I replaced the flame sensor and the limit switch and still having same issue.

Dan Reed (autor) on November 29, 2017:

Ray, Sounds likely the pressure switch is either bad or doing it's job because the chimney is blocked or the fan is running too slow to satisfy the pressure switch. Pressure switch is where I would start my assessment.

Dan Reed (autor) on November 29, 2017:

Vick, It sounds to me like if this problem occurred at the same time as your repairs, you've gotten something in the wiring incorrect. I would advise you revisit this to be sure. Is it possible you have the transformer wired to the board in the wrong spot thus applying constant power to the circuit?